Results (12)
Search Parameters:
Keyword: CalibrationDEM models Calibration and Application to Simulate the Phosphate Ore Clogging
In different areas of industry (mining, food processing, pharmaceutical, manufacturing…), the problem of grain, aggregate and clusters flow arises during the handling activities especially loading and unloading. Thus, the study and control of the parameters that govern the flow of the granular medium and its interaction with its environment are key parameters to achieve the…
Read MoreEye Feature Extraction with Calibration Model using Viola-Jones and Neural Network Algorithms
This paper presents the setup of eye tracking calibration methodology and the preliminary test results of the training model from the eye tracking data. Eye tracking requires good accuracy from the calibration process of the human eyes feature extraction from facial region. Viola-Jones algorithm is applied for this purpose by using Haar Basic feature filters…
Read MoreOmni-directional Multi-view Image Measurement System in the Co-sphere Framework
This study presents an “Omnidirectional multi-view image measurement system”, which can be used to provide multi-camera 3D reconstruction and multi-view image information. Its characteristic is that four cameras take images from multiple perspectives in the co-sphere framework. The C0 is the middle camera fixed as the geometric center point of measurement, and provides a front…
Read MorePerformance Evaluation of a Gamified Physical Rehabilitation Balance Platform through System Usability and Intrinsic Motivation Metrics
Motivation significantly influences the outcome in the rehabilitation of patients. Several developments have been made to assess and increase patient motivation by addressing factors linked to motivation such as the personality of the patient, professional administering rehabilitation, and the rehabilitation environment. The main objective of the study is to evaluate the reliability of a gamified…
Read MoreEvaluation of Type A Uncertainty in a Network Analyzer From 300 kHz to 8.5 GHz
Network Analyzer is equipment widely used for the execution of radio frequency application scattering parameters. Throughout absolute reading the scattering parameter measured. An absolute reading does not include error, drift, offset, linearity, resolution, coefficient of sensitivity and several other variables that will contribute to the measured measurement dispersion. Type A evaluations of measurement uncertainty clarified…
Read MoreEvaluation of Uncertainty Measurement Calculation for Vector Network Analyzer From 300 kHz to 8.5 GHz
Increasing the telecommunications products that allow Vector Network Analyzer is becoming more common tools to measure the S-Parameter. It will be an absolute number from the S-Parameter measurements produced in real and imaginary, other words it is also known as the product of the calculation. The calculation findings do not include the systematic and random…
Read MoreStress Level Classification Using Heart Rate Variability
The research programme reported in this paper is set within the framework of our research under the theme of ICT support for Active Healthy Ageing (AHA). This longitudinal empirical research is focused on the study of the impact on the management of cardio-vascular disease if supported by sustained health monitoring using wearable connected devices. One…
Read MoreExtending the Life of Legacy Robots: MDS-Ach via x-Ach
Our work demonstrates how to use contemporary software tools on older or “legacy” robots while keeping compatibility with the original control, tools, and calibration procedures. This is done by implementing a lightweight middle-ware called MDS-Ach connected directly to the hardware communications layer of the robot’s control system. The MDS-Ach middle-ware, which relies on the x-Ach…
Read MoreA Ubiquitous and Configurable Wrist-Worn Sensor Node in Hazardous Gases Detection
The monitoring of environmental parameters is a critical topic in occupational medicine. With advances in technology, during the recent years, the wearable sensors are widely used to evaluate the ambient parameters. In this paper a compact, small, light-weighted, and configurable sensor node in three physical layers for prolonged chemical ambient monitoring is described. The device…
Read MoreAn Optical-based Fingertip Force Sensor
This work introduces the design and prototype development of a novel optical-based fingertip force sensor, which is integrated in a bio-mimetic finger for robotic and prosthetic manipulation. Given the optical nature of the sensor, the proposed device is free of any electrical and metal components. Accordingly, the design improves manipulation of objects with high electromagnetic…
Read MoreA Secure Automated Elevator Management System and Pressure Sensor based Floor Estimation for Indoor Mobile Robot Transportation
In this paper, a secure elevator handling system is presented to enable a flexible movement of wheeled mobile robots among laboratories distributed in different floors. The automated handling system consists mainly of an ADAM module which has the ability to call the elevator to the robot’s current floor and to request the destination floor. The…
Read MoreA Way for Measuring the Temperature Transients of Capacitors
With the increasing integration level of electronic circuits management of the generated heat became one of the most important design aspects. Beside the semiconductor components capacitors are also affected by the elevated temperature. In this paper a new thermal characterization method is proposed adopting the thermal transient measurement technique for capacitors utilizing the capacitance itself…
Read More
